Amnio Abby® - Ultrasound Guided Invasive Procedures Simulator

Brand: Adam Rouilly
SKU AR60

Skills

  • A range of easy and more difficult procedures can be experienced by varying fetal position, abdominal layers, amniotic fluid volume and placental position enhancing simulation for both new trainees and experienced clinicians 
  • Visualisation under ultrasound of key anatomical structures including abdominal wall, placenta, fetus, umbilical cord and amniotic fluid 
  • Identification of a suitable needle entry point in the simulated abdomen
  • Monitoring of the needle path under
  • real-time ultrasound guidance 
  • Successful withdrawl of an amniotic fluid sample
  • Transplacental needle approach simulation (via placement of the placenta and adjustment of the amniotic volume)
  • Chorionic villus sampling (CVS) procedures 
  • Clinical planning and team work before, during and after invasive procedures
  • Patient communication

Supplementing Invasive Procedures Competency

  • As Non-invasive Prenatal Testing (NIPT) and other techniques reduce the need for amniocentesis  and other ultrasound guided diagnostic procedures,  trainees and operator skills can be enhanced using this realistic simulator
  • To remain proficient, guidelines state “competency should be maintained by carrying out at least 30 ultrasound guided invasive procedures per annum”1
  • Amnio Abby® can help operators to have sufficient confidence to perform more advanced techniques such as cordocentesis and intrafetal procedures that will continue to be required even with the decline in diagnostic invasive tests

1 Professor Z Alfirevic FRCOG, Mr SA Walkinshaw FRCOG and Professor MD Kilby FRCOG. (2010). Amniocentesis and Chorionic Villus Sampling, Green–top Guideline No. 8. London. Royal College of Obstetricians and Gynaecologists, pp. 5 - 6 

Features


  • Model offers an anatomically correct and sonographically realistic sciatic nerve in the right leg positioned within a soft foam leg form
  • Simulated anaesthetics can be injected into the mannequin to aid the user in learning to perform the entire ultrasound guided nerve block procedure
  • Injected fluids are automatically expelled so that the model can be used repeatedly for training
  • This ultrasound training model is constructed using Blue Phantom's patented SimulexUS™ ultra-durable tissue and produces extremely realistic ultrasound images. The materials used matches the acoustic characteristics of actual human tissue so the user experiences the same quality expected from imaging patients in the clinical environment. Uncompromising quality allows clinicians to utilize the model repeatedly reducing the necessity for purchasing replacement parts
  • This model will perform well using any ultrasound imaging system configured with the appropriate transducer (recommended ultrasound transducer; high frequency linear array ultrasound probe 5.0 - 12 MHz)
  • Contains two tissue modules:
    • Proximal sciatic nerve module
    • Distal bifurcating sciatic nerve bundles
  • Injected simulated anaesthetics can be used to verify needle tip location and to practice the entire regional anaesthesia procedure
  • Injected simulated anaesthetics are automatically expelled
  • Product specification:
  • L 81cm W 20cm H 20cm
  • Weight 11.5 Kg

Includes



  • 2 abdominal layers, fetal sac with 15 week-old sized fetus and umbilical cord, separate placenta, sac filling syringe and tubing, base and carrying case

Video