Skip to content

PacerMan System

Brand: Simulab
SKU PM-2101
Original price $50,658.80 - Original price $50,658.80
Original price
$50,658.80
$50,658.80 - $50,658.80
Current price $50,658.80

Simulab's PacerMan® System is the first and only high-fidelity simulator for immersive transvenous pacing training—from needle insertion to electrical capture using all the clinical equipment. With PacerMan, clinicians can practice the entire procedure—including identifying intrinsic bradycardias, assessing intracardiac waveforms and manipulating output and rate with a pacing generator.

Simulab's patented SimuSensor® technology powers PacerMan, replicating a true clinical workflow by allowing the learner to use their own pacing generator to trigger patient responses on a simulated patient monitor. PacerMan can be set on Instructor Mode, with specifically chosen scenario parameters or randomized Student Mode. Both settings include options for multiple outcomes and offer hands-on learning anytime, anywhere.

<p data-mce-fragment="1"><span data-preserver-spaces="true" data-mce-fragment="1"><br><strong data-mce-fragment="1">PacerMan System</strong></span></p>
<ul>
<li><span data-preserver-spaces="true" data-mce-fragment="1">Durable replaceable tissue for full catheterization using an introducer and temporary pacing lead</span></li>
<li><span data-preserver-spaces="true" data-mce-fragment="1">Ultrasound-guided venous identification and access with fluid aspiration</span></li>
<li><span data-preserver-spaces="true" data-mce-fragment="1">Randomized Student and Instructor Modes with multiple outcome options</span></li>
<li><span data-preserver-spaces="true" data-mce-fragment="1">Simulated Patient Monitor with:</span></li>
<li><span data-preserver-spaces="true" data-mce-fragment="1">Real-time vitals including heart rate, arterial blood pressure, non-invasive blood pressure, and oxygen saturation.</span></li>
<li><span data-preserver-spaces="true" data-mce-fragment="1">Simulated defibrillator for transcutaneous pacing and transition of care</span></li>
<li><span data-preserver-spaces="true" data-mce-fragment="1">ECG tracing that presents intracardiac location waveforms representing the Superior Vena Cava, Right Atrium, Right Ventricle, Inferior Vena Cava, Pulmonary Artery and Current of Injury Pattern.</span></li>
<li><span data-preserver-spaces="true" data-mce-fragment="1">Set up an additional monitor to simulate a stand-alone patient monitor.</span></li>
<li><span data-preserver-spaces="true" data-mce-fragment="1">Bluetooth compatibility for untethered training</span></li>
<li><span data-preserver-spaces="true" data-mce-fragment="1">Touchscreen compatibility for Windows 7 OS or higher</span></li>
<li><span data-preserver-spaces="true" data-mce-fragment="1">Battery or wall power supply to offer flexibility</span></li>
</ul>
<p data-mce-fragment="1"><span data-preserver-spaces="true" data-mce-fragment="1">
</span></p>

<p data-mce-fragment="1"><span data-preserver-spaces="true" data-mce-fragment="1"><br><strong data-mce-fragment="1">PacerMan System</strong></span></p>
<ul>
<li><span data-preserver-spaces="true" data-mce-fragment="1">Learn to manipulate the pacing generator and interact with a transvenous pacing catheter and introducer kit. – Not included</span></li>
<li><span data-preserver-spaces="true" data-mce-fragment="1">Obtain electrical capture</span></li>
<li><span data-preserver-spaces="true" data-mce-fragment="1">Refine amperage of electrical output and pulse rate in real time.</span></li>
<li><span data-preserver-spaces="true" data-mce-fragment="1">Improve procedural performance through instructor-led pre-defined competencies or self-directed practice</span></li>
<li><span data-preserver-spaces="true" data-mce-fragment="1">Practice medical decision making based on outcome options</span></li>
<li><span data-preserver-spaces="true" data-mce-fragment="1">Train using blind and ECG guided techniques</span></li>
<li><span data-preserver-spaces="true" data-mce-fragment="1">Increase team engagement with multi-disciplinary scenario-based learning.</span></li>
<li><span data-preserver-spaces="true" data-mce-fragment="1">The instructor can choose from a series of scenarios by defining successful capture, thresholds and placement outcomes.</span></li>
</ul>
<p data-mce-fragment="1"><span data-preserver-spaces="true" data-mce-fragment="1">
</span></p>

<br>
<p data-mce-fragment="1"><span data-preserver-spaces="true" data-mce-fragment="1"><br><strong data-mce-fragment="1">PacerMan System</strong></span></p>
<p data-mce-fragment="1"><span data-preserver-spaces="true" data-mce-fragment="1">Size: 30.5” x 16” x 11” <br>Weight: 26 lbs</span></p>